Search Constraints
Filtering by:
Keyword
Alphasense OPC-N3 performance during
Remove constraint Keyword: Alphasense OPC-N3 performance during
1 entry found
Number of results to display per page
Search Results
-
- Description:
- Abstract: Data for Performance evaluation of the Alphasense OPC-N3 and Plantower PMS5003 sensor in measuring dust events in the Salt Lake Valley, Utah This data file was used to estimate the performance of the Alphasense OPC-N3 and PMS5003 sensor in measuring ambient PM10, especially during dust events, and to obtain correction factors to correct the PMS5003 data. During April 2022, the OPC-N3 and PMS5003 sensors were collocated with federal equivalent method (FEM)at two Utah Division of Air Quality (UDAQ) sites: Hawthorne (HW) station and Environmental Quality (EQ) station. One residential site (RS)was also tested, with OPC-N3 and PMS5003 collocated with GRIMM portable aerosol spectrophotometer. The FEM data (PM2.5 and PM10 concentrations) and meteorological parameters (wind speed, wind direction, relative humidity, and temperature) for the two UDAQ sites were downloaded from the EPA website. The Excel sheet contained all the raw data and the processed data. The FEM, OPC-N3, and PMS5003 measurements were labeled as FEM-YYY, OPC-YYY, and PMS-YYY, where YYY represents the sites nomenclature, i.e., HW, EQ, and RS. The sheet labeled “HW”, “RS”, and,” EQ” contained the raw measurements (meteorological, PM10, and PM2.5 (whenever applicable)) for the sites. The sheet” PM-ratio-based correlation” provided the data used to get the PM-ratio-based correlation. Briefly, based on the ratio of FEM-HW PM2.5/PM10, the FEM-HW and PMS-HW PM10 measurements were segregated into six bins: PM2.5/PM10: <0.2, 0.2-0.3, 0.3-0.4, 0.4-0.5, 0.5-0.7, and >0.7. For each bin, the co-located PMS-HW PM10 concentrations were linearly regressed against the FEM-HW PM10 concentrations to obtain correction factors (slope and intercept). These correction factors were later used to correct the PMS PM10 concentrations at the other two locations (RS and EQ), presented in the sheets with labels “RS correction using GRIMM ratio”, “RS correction using opc ratio” and “EQ corrected using EQ ratio”. Each sheet also includes the calculation of RMSE and NRMSE of OPC-YYY and PMS-YYY against FEM-YYY, with YYY as the site nomenclature.
- Keyword:
- Plantower PMS5003, dust events, air pollution, air quality, ppticle particle counters, PM10, AQI, particulate matter, PM sensor, and Alphasense OPC-N3 performance during
- Subject:
- air pollution
- Creator:
- Kelly, Kerry and Kaur, Kamaljeet
- Owner:
- Based Near Label Tesim:
- Salt Lake City, Utah, United States
- Language:
- English
- Date Uploaded:
- 10/20/2022
- Date Modified:
- 06/03/2024
- Date Created:
- 2022-04-01 to 2022-04-30
- License:
- CC BY – Allows others to use and share your data, even commercially, with attribution.
- Resource Type:
- Dataset
- Identifier:
- https://doi.org/10.7278/S50d-xbns-3ge3